Engineering Design Manual

 

Engineering Design Manual
(complete document)

 

 
 

 

TABLE OF CONTENTS

Appendix B, Estimating Construction Cost for Bonding
Appendix F, Construction Details
General Details:  
G1 - LIST OF FIGURES G11 - RESTRAINT OF VERTICAL OFFSET
G2 - LIST OF FIGURES G12 - CASING INSTALLATION
G3 - LIST OF FIGURES G13 - PAVEMENT PATCH ON PRIVATE PROPERTY
G5 - STANDARD NOTES G15 - IMPERVIOUS TRENCH CHECK
G6 - PIPE BEDDING AND ENCASEMENT G16 - MARKER POSTS AND TRACER PEDESTALS
G7 - CONCRETE THRUST BLOCK G20 - VAULT FEATURES
G8 - THRUST BLOCK DIMENSIONS G21 - VAULT NOTES
G9 - LINE ANCHOR G22 - VAULT LADDER
G10 - LINE ANCHOR ON LARGE PIPE G23 - HATCH SAFETY FEATURES
  G24 - Electronics at Magnetic Meter
Cathodic Protection:  
CP1 - BONDING OF PIPE AND FITTING CP8 - INSULATING FLANGE TEST STATION WITH ANODES
CP2 - THERMITE WELD CP9 - TEST STATION AT STEEL CASING
CP3 - COATING OF MECHANICAL JOINTS CP10 - TEST STATION BY PEDESTAL
CP4 - ANODE PLACEMENT CP11 - TEST STATION BY BOX AT GRADE
CP5 - SPLICE OF ANODE TO HEADER CABLE CP12 - HOT SPOT PROTECTION-COATING AND ANODE
CP6 - ANODE BED AND TEST STATION CP14 - HOT SPOT PROTECTION-ANODE PLACEMENT
CP7 - INSULATING FLANGE TEST STATION  
Water:  
W1 - VALVE BOX W22 - SERVICE CONNECTION FOR 3/4" METER-RESIDENTIAL USE
W2 - TEMPORARY BLOW-OFF W23 - SERVICE CONNECTION FOR 3/4" AND 1" METERS - COMMERCIAL USE
W4 - AIR RELEASE W24 - WATER SERVICE BY JACK AND BORE
W8 - TABLE OF ALLOWABLE LEAKAGE W25 - WATER METER IN SIDEWALK OR SLAB
W9 - HYDRANT NOTES W26 - DUAL WATER METER SETTING
W10 - FIRE HYDRANT ALONG STREET W27 - SERVICE CONNECTION FOR 1 1/2" AND 2" OMNI C2 METERS
W11 - FIRE HYDRANT BEHIND DITCH  
W12 - DEAD END HYDRANT W29 - 3", 4" AND 6" OMNI C2, OMNI T2 OR ACCUMAG METER IN VAULT
W13 - HYDRANT BOLLARDS W30 - 3", 4" OR 6" OMNI C2, OMNI T2 OR ACCUMAG INDOORS
W19 - FIRE SERVICE TO SINGLE FAMILY ATTACHED HOME W31 - SERVICE ENTRANCE WITH INDOOR METER
W20 - FIRE SERVICE CONNECTION W32 - 3/4" OR 1" SUBTRACTION OR INDUSTRIAL PROCESS METER
W21 - SAMPLING STATION W33 - 1 1/2" OR 2" OMNI C2 SUB. OR INDUST. PROCESS METER
Reclaimed Water:  
R1 - REUSE VALVE BOX R11 - REUSE SERVICE FOR 2" ULTRASONIC METER
R2 - REUSE AIR RELEASE R12 - 2" ACCUMAG REUSE METER
R3 - TERMINUS BY FLUSHING HYDRANT R13 - 3", 4" OR 6" ACCUMAG REUSE METER IN VAULT
R4 - TEMPORARY TERMINUS BY BLOW-OFF R14 - REUSE SERVICE ENTRANCE WITH INDOOR METER
R5 - REUSE FLUSHING HYDRANT BELOW GRADE R15 - 3/4" OR 1" REUSE METERS INDOORS
R6 - REUSE FLUSHING HYDRANT ABOVE GRADE R16 - 3", 4" OR 6" ACCUMAG REUSE METER INDOORS
R9 - REUSE SAMPLING STATION R18 - WARNING SIGNS AT REUSE FIXTURES
R10 - REUSE SERVICE FOR 3/4" AND 1" METERS R20 - STANDARD NOTES FOR RECLAIMED WATER
Sewer Gravity:  
S1 - MANHOLE S7 - ADVANCE BLASTING
S2 - SIDE VENT FOR MANHOLE S10 - LATERAL
S3 - TOP VENT FOR MANHOLE S11 - LATERAL WITH VERTICAL BENDS
S4 - OUTSIDE DROP CONNECTION S12 - SANITARY CLEANOUT
S5 - INSIDE DROP CONNECTION S13 - WATER METER SETTING-SEWER ONLY ACCOUNTS
  S20 - TABLE OF ALLOWABLE LEAKAGE
Sanitary Force Main:  
FM1 - FORCE MAIN AIR RELEASE  
Low Pressure Collection:  
LPC1 - GRINDER PUMP LPC5 - FLUSHING CONNECTION
LPC2 - ELECTRICAL SUPPLY TO PUMP LPC6 - LOCATION OF VALVES FOR IN-LINE FLUSHING CONNECTION
LPC3 - LOW PRESSURE LATERAL LPC7 - TERMINAL FLUSHING CONNECTION
LPC4 - SERVICE BY TAP LPC8 - AIR RELEASE FOR LOW PRESSURE SEWER
Pretreatment:  
PT1 - GREASE INTERCEPTOR  
Appendix G, Materials

Approved Materials List

When the Product Review Committee makes determinations that materials should be added or deleted, or an approval/disapproval/conditional status be revised, the Committee Chair will update the table Approved Materials List. Determinations appear in red text with a revision date within the Approved Materials List. The document will be updated monthly or when revisions are necessary. 

Product Review Procedures

Interim Period – Materials Clarifications – Q & A
 

General Conditions of the Construction Contract